ERRORGTFS Schedule notice

An interval ends before it starts

start_and_end_range_out_of_order
Severity
ERROR
Files to check
See report
Report fields
7
Documentation
Curated

Diagnosis

What this notice means

The reported end date or time precedes its start.

Operational effect

Why it matters

The period or stop-time event cannot be interpreted in the intended order.

Scope

Files to check and report fields

Use the file or input resource identified in the report. Check the message and available context fields; runtime failures may not identify a GTFS row.

Report fieldTypeMeaning
csvRowNumberintegerThe row number of the faulty record.
endFieldNamestringThe end value's field name.
endValuestringThe end value.
entityIdstringThe faulty service id.
filenamestringThe name of the faulty file.
startFieldNamestringThe start value's field name.
startValuestringThe start value.

Repair

How to fix it

  1. 1

    Compare startFieldName, startValue, endFieldName, and endValue with the source timetable.

  2. 2

    Correct the mistaken boundary. For overnight stop times within one service day, use hours above 24 where allowed instead of resetting the clock to zero.

  3. 3
    Check the result

    After a repair, rebuild the archive and validate it again. Confirm that the affected records are correct and that no new related notices appeared. A reviewed warning or informational notice may remain when it describes intentional, supported data.