ERRORGTFS Schedule notice

The access flag is set on the wrong location type

stop_access_specified_for_incorrect_location
Severity
ERROR
Files to check
1
Report fields
5
Documentation
Curated

Diagnosis

What this notice means

stop_access_specified_for_incorrect_location is an error in a GTFS Schedule validation report: the access flag is set on the wrong location type. Start with stops.txt.

stop_access is populated on a station, entrance, generic node, or boarding area.

Operational effect

Why it matters

The flag does not apply to that kind of location.

Scope

Files to check and report fields

Report fieldTypeMeaning
csvRowNumberintegerThe row of the faulty record.
locationTypeenumstops.location_type of the faulty record.
stopAccessenumThe stops.stop_access of the faulty record.
stopIdstringThe stops.stop_id of the faulty record.
stopNamestringThe 'stops.stop_name' of the faulty record.

Repair

How to fix it

  1. 1

    Inspect the reported row's location_type in stops.txt.

  2. 2

    Clear stop_access where forbidden, or correct a wrongly classified location. Use the flag only on an eligible stop/platform with a parent station.

  3. 3
    Check the result

    After a repair, rebuild the archive and validate it again. Confirm that the affected records are correct and that no new related notices appeared. A reviewed warning or informational notice may remain when it describes intentional, supported data.